Blickenstorfer et al. propose a simpler configuration of focal molography that uses darkfield illumination by total internal reflection (TIR) instead of a waveguide mode. Their real-time streptavidin experiments show high resolution and robustness.
The Challenge: Limits of Waveguide Illumination
Earlier focal molography illuminated the sensor with a guided mode. This gives very good resolution, but it brings wavefront instabilities and a high refractive index contrast at the waveguide interfaces. Waveguides and grating couplers also add manufacturing cost.
The Approach: Total Internal Reflection Focal Molography (TIR-M)
The authors derive the coherent binding pattern, describe the fabrication process and derive the quantitative readout formula. They then perform a background and noise analysis. Real-time binding of 500 pM streptavidin was measured in buffer and in 100 µM bovine serum albumin (BSA), in triplicates.
Key Results for TIR-M Noise and Robustness
- Baseline noise: root mean square values of 0.051 to 0.070 pg/mm² over 100 seconds, without drift correction. Guided-wave molography (GW-M) reported about 0.08 pg/mm².
- Long experiments: noise as low as 4 fg/mm² over almost 20 minutes, which corresponds to about 6500 streptavidin molecules on the mologram.
- Compared with GW-M: GW-M noise was up to a factor of 3 higher for experiment durations of 100 to 1000 seconds.
- Non-specific binding: a control with 100 µM BSA and no analyte showed only a slight drift upon injection.
Why It Matters for Diffractometric Sensors
TIR-M has advantages in measurement stability, quantification accuracy, substrate complexity and multichannel fluorescence microscopy. GW-M keeps advantages in shot noise, measurements faster than 1 second and contact-free chips. The authors conclude that the better choice depends on the application.
More resources
Oct 2026
High-throughput thermodynamic fingerprinting of protein–ligand interactions by DNA-directed focal molography
Oehninger, Notova, Frutiger
Oehninger, J., Notova, S., & Frutiger, A. (2026). PLOS One, 21(10), e0354008. https://doi.org/10.1371/journal.pone.0354008
Download after a short form
Oct 2026
Same target, different stickiness: polyreactivity of therapeutic antibodies
lino Biotech AG
Six clinical antibodies, including two same-target pairs, ranked by polyreactivity against an eight-ligand panel on one focal molography chip. Briakinumab scored 69-fold above ...
Download after a short form
Oct 2026
One on-DNA ligand against many targets: selectivity profiling for DEL hit validation
lino Biotech AG
On-DNA oncoFAP profiled against human, mouse and canine FAP and five unrelated proteins on one focal molography chip layout. Full kinetics on every species variant, flat responses ...
Download after a short form